Big
consumers have to use many cylinders. SSFCI CO2 manifold system
enables a consumer to draw CO2 gas at one place and avoid mishandling
of CO2 cylinders at different places at the workfloor. The battery
system of using the cylinders at one place eliminates the carriage
of individual cylinders at different locations where MIG welding
sets/user systems are located.
The SSFCI manifold system incorporates a special system, through
the pipeline laid across machine on the shop floor. With our Pressure
Reduction Station the pressure of the gas is reduced so that low
pressure gas (as required by the user) is sent through the pipeline.
With proper instrumentation and inter-locking, safe system is designed
for trouble free service.
|
 |
| |
CO2
is transported in liquid phase either in cylinders or in storage
tankers but it is used in gaseous state in beverages and other uses.
CO2 is evaporated and expanded to lower pressure. In the
expansion operating cooling occurs which can choke the entire system,
resulting in pressure oscillation and thus CO2 losses can take place.
|
1.
No internal freezing. 2. No pressure
oscillation
3. Clean CO2 as the impurities get filtered off.
4. No interruption in CO2 supply during cylinder change.
Saving of energy, CO2 and time are the main advantage.
5. No outside heater/steam required. 6. Neat surroundings.
7. No full time operator required.
|
| |
SSFCI
manifold system makes it possible to supply gaseous CO2 at any desired
outlet pressure. We can install up to 4 outlets with 4 different
outlet pressure as required. Gas outflow pressure can be varied
between 1 to 16 bars. The quality of CO2 required determines the
number of CO2 cylinders to be connected per hour. Our engineers
will erect the complete system for you. The time for installation
is minimum as the entire system is pre-assembled and tested at our
site.
Since,
in many courtries CO2 supplies are done in the cylinders of different
sizes, heights & capacities, therefore, the SSFCI manifold system,
is modified to suit such conditions. It must be understood that
the system is designed to handle pure, moisture free CO2 gas as
per IS/BS/ASME Standards. If the gas is not of proper specifications
and contains moisture or oil etc, extra features like Dryers
and Oil Filters can be incorporated at extra cost.
Alarm System can be provided to indicate low pressure in cylinder
when these are exhausted.
|
| 1. |
Main
Room Temperature Reduction Station |
1
No. |
| 2. |
Mano
meter/Pressure gauge |
1
set |
| 3. |
Temperature
gauge |
1
set |
| 4. |
Drain
Valve |
1
set |
| 5. |
Valve |
1
set |
| 6. |
Pressure
Reducing Valves |
2
Nos. |
| 7. |
Safety
Valves |
1
set |
| 8. |
Two
way valve |
1
set |
| 9. |
Wall
attachment clamp |
1
set |
| 10. |
Joint
Packing |
1
set |
| 11. |
Valve
Adopters set |
- |
| 12. |
Micro
filter (Optional) |
- |
| 13. |
High
pressure SS Hose pipe |
1
set |
| 14. |
Header
pipe line for cylinders connections |
- |
| 15. |
Alarm
& Signal for low pressure in cylinders |
- |
| 16. |
Isolation
Valve |
- |
|